BOWMAN HEAT EXCHANGERS FOR INDUSTRIAL LAND BASED APPLICATIONS

Page Updated: 01-Jan-24

EC TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
EC80-1425-1 4 80 80 £175
EC100-1425-2 9 92 80 £210
EC120-1425-3 13 77 77 £265
EC140-1425-4 17 68 72 £312
EC160-1425-5 22 64 66 £392
Body lengths for the above coolers: EC80 98mm, EC100 184mm, EC120 270mm, EC140 368mm, EC160 496mm.
All bodies 84mm diameter.
Oil type ISO VG 37, Oil outlet temperature 50 degC Oil pressure drop 100 kPa Water inlet temperature 25 degC Water pressure drop 50 kPa
For LAND-BASED installations, standard units are supplied with cast iron end covers.
Where sea water is used for cooling, MARINE specification end covers MUST be used.
High Temperature Standard products are suitable for cooling oil up to 120 °C but our comprehensive range offers units for applications where hydraulic oil is required to run at temperatures up to 200 °C.
Mining Applications For deep underground mining applications, where ambient air temperatures are high, Bowman offer a range of oil coolers suitable for use with water pressures up to 35 bar.
SAE Flanges: On Bowman GL size hydraulic oil coolers and larger, SAE oil flange connections are provided on the shell side of the unit, whilst the smaller EC, FC and FG models feature BSP connections as standard.
Sealing rings are available on some units enabling easy service and maintenance of the cooling tubes without having to drain the hydraulic circuit.
Tube Stack Options: Whilst cupronickel is the standard tube material on all units, but titanium tube stacks are also available as options to suit customer requirements.

FC TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
FC 80-1426-1 13 140 140 £370
FC100-1426-2 19 145 135 £393
FC120-1426-3 26 116 125 £529
FC140-1426-4 35 105 120 £627
FC160-1426-5 45 96 108 £718
Body lengths for the above coolers: FC80 178mm, FC100 264mm, FC120 362mm, FC140 490mm, FC160 636mm.
All bodies 108mm diameter.
As per description provided for EC Coolers

FG TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
FG 80-1427-1 28 192 185 £521
FG100-1427-2 37 190 175 £563
FG120-1427-3 50 160 160 £649
FG140-1427-4 62 160 150 £804
FG160-1427-5 79 145 135 £989
FG200-1427-7 112 100 105 £1,735
Body lengths for the above coolers: FG80 28m6m, FG100 364mm, FG120 492mm, FG140 638mm, FG160 816mm, FG200 1224mm.
All bodies 162mm diameter.
As per description provided for EC Coolers

GL TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
GL140-1428-2 56 300 300 £888
GL180-1428-3 73 285 280 £1,088
GL240-1428-4 93 280 260 £1,293
GL320-1428-5 114 270 240 £1,665
GL400-1428-6 146 240 220 £1,941
GL480-1428-7 172 235 205 £2,364
Body lengths for the above coolers: GL140 362mm, GL180 490mm, GL240 636mm, GL320 814mm, GL400 1016mm, GL480 1220mm.
All bodies 162mm diameter.
As per description provided for EC Coolers

GK TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
GK190-1658-3 112 460 420 £1,566
GK250-1658-4 144 445 385 £1,948
GK320-1658-5 181 430 355 £2,340
GK400-1658-6 221 420 325 £2,994
GK480-1658-7 259 400 300 £3,677
GK600-1658-8 329 365 275 £4,358
Body lengths for the above coolers: GK190 490mm, GK250 636mm, GK320 814mm, GK400 1228mm, GK600 1738mm.
All bodies 198mm diameter.
As per description provided for EC Coolers

JK TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
JK190-1661-3 145 830 650 £2,655
JK250-1661-4 186 740 550 £2,996
JK320-1661-5 232 690 500 £3,287
JK400-1661-6 283 650 460 £4,071
JK480-1661-7 335 620 430 £4,697
JK600-1661-8 401 600 400 £5,372
Body lengths for the above coolers: JK190 490mm, JK250 636mm, JK320 814mm, JK400 1016mm, JK480 1220mm, JK600 1524mm.
All bodies 232mm diameter.
As per description provided for EC Coolers

PK TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
PK190-1669-3 212 1600 900 £3,173
PK250-1669-4 270 1240 840 £4,158
PK320-1669-5 336 1060 750 £5,394
PK400-1669-6 414 950 700 £6,073
PK480-1669-7 497 890 650 £7,124
PK600-1669-8 660 750 600 £8,393
Body lengths for the above coolers: PK190 490mm, PK250 636mm, PK320 814mm, PK400 1016mm, PK480 1220mm, PK600 1524mm.
All bodies 278mm diameter.
As per description provided for EC Coolers

RK TYPE LAND BASED HYDRAULIC OIL COOLERS

Type HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
RK400-1698-6 570 1450 1180 £8,965
RK600-1698-8 900 1240 850 £12,928
Body lengths for the above coolers: RK400 951mm, RK600 1298mm.
All bodies 338mm diameter.
As per description provided for EC Coolers

HEADERTANK/HEAT EXCHANGERS FOR LAND BASED APPLICTIONS CAST IRON END CAPS

PRICEBOOK REF HEAT DISSIPATED 
[kW]
MAX OIL  
FLOW  
[l/min]
COOLANT  
FLOW 
[l/min] 
PRICE
EH100-4065-2 TBC TBC TBC £333
EH200-4065-3 TBC TBC TBC £372
FH100-4066-2 TBC TBC TBC £439
FH200-4066-3 TBC TBC TBC £520
FH300-4067-2 TBC TBC TBC £667
FH400-4067-3 TBC TBC TBC £937
GH200-4068-2 TBC TBC TBC £1,251
GH300-4068-3 TBC TBC TBC £1,370
GH400-4068-4 TBC TBC TBC £1,612
KH200-4069-3 TBC TBC TBC £2,622
KH300-4069-4 TBC TBC TBC £3,142
KH400-4069-5 TBC TBC TBC £3,915
JH200-4070-3 TBC TBC TBC £3,641
JH300-4070-4 TBC TBC TBC £4,268
JH400-4070-5 TBC TBC TBC £4,945
PH200-4071-4 TBC TBC TBC £6,343
PH300-4071-5 TBC TBC TBC £7,329
PH400-4071-6 TBC TBC TBC £8,641
Heat exchangers with cast iron end covers for land-based applications with NiBrAl Tubestacks.
Copper tubestacks available as special order. Discount 5% on price. Units suffixed TC
Water Level Switch can be fitted to units KH, JH, PH units at extra cost of £160

CHARGE AIR COOLERS FOR LAND BASED APPLICATIONS

PRICEBOOK REF POWER AIR PORTS WATER PORTS PRICE
EC120-5173-3 120 hp 2" Hose ¾"BSP female C.I. £430
EC140-4217-4 130 hp 2" Hose ¾"BSP female C.I. £484
FC100-5174-2 147 HP 2" Hose 1"BSP female C.I. £412
FG100-5175-2 140 HP 2" Hose ¾"BSP female C.I. £576
GL140-5176-2 255 HP 3" Hose 1¼"BSP female C.I. £940
GK190-5177-3 320 HP 3" Hose 1½"BSP female C.I. £1,664
JK190-5178-3 - - Cast Iron £2,324
PK190-5179-3 - - Cast Iron £3,760
PK250-5979-4 - - Cast Iron £4,523
RK250-5980-4 - - Cast Iron £6,733
Supplied with Cast Iron End Covers. For use with industrial land based applications.

STAINLESS STEEL HEAT EXCHANGERS - SF TYPE

ITEM DESCRIPTION HEAT  
DISSIPATED  
[kW]
OIL  
FLOW  
[l/min]
WATER  
FLOW  
[l/min]
PRICE
SF4511-4 140 580 740 £8,848
SF4511-6 224 550 650 £9,736
SF4511-8 354 500 520 £11,033
SF4511-9 536 460 480 £12,239
316L stainless steel is used throughout these heat exchangers, with 9.5mm tube for the tube stack providing efficient heat transfer
Body lengths for the above coolers: 4 834mm, 6 1214mm, 8 1722mm, 9 2230mm
Body Diameter: 219 mm

STAINLESS STEEL HEAT EXCHANGERS - SG TYPE

ITEM DESCRIPTION HEAT  
DISSIPATED  
[kW]
OIL  
FLOW  
[l/min]
WATER  
FLOW  
[l/min]
PRICE
SG4512-4 223 960 1100 £9,624
SG4512-6 358 920 1000 £10,910
SG4512-8 624 740 900 £12,441
SG4512-9 871 750 790 £14,290
316L stainless steel is used throughout these heat exchangers, with 9.5mm tube for the tube stack providing efficient heat transfer
Body lengths for the above coolers: 4 844mm, 6 1224mm, 8 1732mm, 9 2240mm
Body Diameter: 273 mm
All models feature easily removable end covers, which give easy access to the tubes for cleaning. As the tube stack is fixed, all cleaning and maintenance requirements can be carried out without the need to drain the primary circuit
Maximum working pressure shell side (primary) 20 bar.
Maximum working pressure tube side (secondary) 20 bar.
Maximum working oil temperature 200ºC.
Maximum working water temperature 120ºC.
Computer aided software is used to select the correct heat exchanger for your application. Please advise: Primary fluid details (water or oil properties), Primary fluid flow rate, Required water or oil outlet temperature, heat to be dissipated and temperature and source of cooling.

V.A.T. extra on U.K. sales, except Channel Isles.
Packing & Carriage is extra, optimum time route & cost tailored to the clients needs.
Quantity terms available on request.

« Previous Page
Next Page »
We're happy to help. Call +44 (01273) 410025

About Lancing Marine

DIY Engine Marinisation guide

Latest Special Offers

Blog Posts

JABSCO
Bowman
Vetus
VW
Aquafax
Ford
Perkins
Borg Warnder
Payments accepted including bank transfer:
Visa
Mastercard
Maestro
Amex
PayPal